Skip to article frontmatterSkip to article content
Site not loading correctly?

This may be due to an incorrect BASE_URL configuration. See the MyST Documentation for reference.

Some loads never stop: a reciprocating engine bolted to a floor, an unbalanced fan, a rotor, a pump, and a crowd bouncing in time to music all push a structure with a force that repeats. The simplest repeating force is a single sinusoid:

p(t)=p0sin⁡(ωt),p(t) = p_0 \sin(\omega t),

with amplitude p0p_0 and forcing frequency ω\omega (rad/s). This chapter hands that p(t)p(t) to the engine from Chapter 3 and reads the answers straight off the plots. It shows how the response settles into a steady rhythm, why it can blow up near one special frequency, how to turn a measured response curve into a damping estimate, and what happens when the “harmonic” load is really a periodic train of pulses. The recurring idea is the frequency ratio

β=ωωn,\beta = \frac{\omega}{\omega_n},

the forcing frequency measured in units of the structure’s own natural frequency. Almost everything in this chapter is a story about β\beta.

We will carry one system the whole way through: a small machine mounted on a steel frame.

omega_n = 10.00 rad/s    f_n = 1.592 Hz    Tn = 0.628 s
static deflection  u_st = p0/k = 10.0 mm

The quantity ust=p0/ku_\text{st} = p_0/k, the deflection the frame would have if we applied p0p_0 slowly, is our yardstick. Every dynamic amplitude below is reported as a multiple of it.

1From transient to steady state

Switch the machine on at t=0t=0 and the frame does two things at once. It tries to vibrate at its own frequency ωn\omega_n (the transient, which damping kills off), and it is forced to follow the drive frequency ω\omega (the steady state, which lasts as long as the machine runs). Figure 1 separates the two for a drive below resonance, β=0.8\beta = 0.8. The transient is a free vibration of the kind studied in Chapter 2, so it rings at the damped frequency inside a shrinking envelope. The steady state is a plain sinusoid at the drive frequency, and the total response the frame actually performs is their sum, which starts from rest because the transient begins by exactly canceling the steady state.

The response of the machine frame to a harmonic force switched on at t = 0
(\beta = 0.8), split into a decaying transient and a lasting steady state.

Figure 1:The response of the machine frame to a harmonic force switched on at t=0t = 0 (β=0.8\beta = 0.8), split into a decaying transient and a lasting steady state.

The engine produces the total directly, and the next cell overlays it on the closed-form steady state derived just below.

<Figure size 988x403 with 1 Axes>
<Figure size 988x403 with 1 Axes>

Figure 2:Switching on a harmonic force at β=0.8\beta=0.8: the full engine response (solid) and the steady-state sinusoid alone (dashed).

The total response (solid) starts at rest and, after a brief transient, locks onto the steady-state sinusoid (dashed). Two numbers describe that final rhythm, its amplitude and its phase lag behind the force, and the question is where they come from. The transient is just the damped free vibration of Chapter 2, which dies out; the lasting steady state must be a sinusoid at the drive frequency ω\omega (nothing else can balance a sin⁡ωt\sin\omega t on the right-hand side forever). So we try

uss(t)=Csin⁡ωt+Dcos⁡ωt,u_\text{ss}(t) = C\sin\omega t + D\cos\omega t,

a sine and a cosine at the forcing frequency, and let the equation of motion fix the two constants. Differentiating gives u˙ss\dot u_\text{ss} and u¨ss\ddot u_\text{ss}; substituting all three into mu¨+cu˙+ku=p0sin⁡ωtm\ddot u + c\dot u + ku = p_0\sin\omega t and grouping the sin⁡ωt\sin\omega t and cos⁡ωt\cos\omega t terms separately yields

(k−mω2)C−(cω)D⏟coefficient of sin⁡ωt=p0,(cω)C+(k−mω2)D⏟coefficient of cos⁡ωt=0.\underbrace{(k - m\omega^2)C - (c\omega)D}_{\text{coefficient of }\sin\omega t} = p_0, \qquad \underbrace{(c\omega)C + (k - m\omega^2)D}_{\text{coefficient of }\cos\omega t} = 0.

The two sides must match at every instant, so the sine coefficients balance and the cosine coefficients balance: two linear equations for CC and DD. Divide through by kk and use k=mωn2k=m\omega_n^2, so mω2/k=β2m\omega^2/k=\beta^2 and cω/k=2ζβc\omega/k = 2\zeta\beta (recall ζ=c/2mωn\zeta=c/2m\omega_n from Chapter 2 and β=ω/ωn\beta=\omega/\omega_n). Solving the pair gives

C=p0k 1−β2(1−β2)2+(2ζβ)2,D=p0k −2ζβ(1−β2)2+(2ζβ)2.C = \frac{p_0}{k}\,\frac{1-\beta^2}{(1-\beta^2)^2+(2\zeta\beta)^2}, \qquad D = \frac{p_0}{k}\,\frac{-2\zeta\beta}{(1-\beta^2)^2+(2\zeta\beta)^2}.

Finally, collapse the sine-plus-cosine into a single shifted sine, Csin⁡ωt+Dcos⁡ωt=u0sin⁡(ωt−ϕ)C\sin\omega t + D\cos\omega t = u_0\sin(\omega t-\phi) with amplitude u0=C2+D2u_0=\sqrt{C^2+D^2} and lag tan⁡ϕ=−D/C\tan\phi=-D/C. The common denominator makes the square root collapse neatly, and we arrive at

u0=p0k Rd,Rd(β,ζ)=1(1−β2)2+(2ζβ)2,tan⁡ϕ=2ζβ1−β2.u_0 = \frac{p_0}{k}\,R_d, \qquad R_d(\beta,\zeta) = \frac{1}{\sqrt{(1-\beta^2)^2 + (2\zeta\beta)^2}}, \qquad \tan\phi = \frac{2\zeta\beta}{1-\beta^2}.

RdR_d is the deformation response factor: the dynamic amplitude divided by the static deflection p0/kp_0/k. Notice the physics already hiding in the denominator: the spring contributes the 1, inertia the −β2-\beta^2, and the dashpot the 2ζβ2\zeta\beta; when β→1\beta\to1 the first two cancel and only damping is left to limit the amplitude. We will confirm RdR_d in a moment by measurement instead of algebra: sweep ω\omega, read the steady amplitude off each run, and divide. First, Example 1 evaluates (6) by hand for the run of Figure 2.

The next cell measures the same two numbers from the tail of the engine run, the amplitude as half the peak-to-peak swing of the last forcing cycle and the lag from the time of its last positive peak.

measured amplitude  u0 = 27.05 mm
formula  (p0/k)*Rd     = 27.12 mm
Rd = 2.7050   (closed form 2.7116)
60-cycle run: u0 = 27.12 mm   lag phi = 0.219 rad   (closed form 0.219 rad = 12.5 deg, time lag 0.027 s)

They match to a fraction of a percent. The 0.07 mm gap in the amplitude is just the last sliver of transient that has not quite died in this 12-period run, exactly what Figure 2 shows. The 60-cycle run, with the transient long gone, recovers both the amplitude and the lag to the digits printed.

2The resonance curves: RdR_d versus β\beta

Now repeat that measurement at every frequency: we sweep β\beta from near zero to 3, run the engine to steady state at each value, read the amplitude, and divide by p0/kp_0/k. Repeating the sweep for several damping ratios traces the famous family of resonance curves.

<Figure size 962x546 with 1 Axes>
<Figure size 962x546 with 1 Axes>

Figure 3:The deformation response factor Rd=u0/(p0/k)R_d=u_0/(p_0/k) against the frequency ratio β=ω/ωn\beta=\omega/\omega_n for four damping ratios (markers = engine sweep; lines = closed form (6)).

Read the curves of Figure 3 from left to right. At low β\beta (slow forcing) Rd→1R_d \to 1: the structure has time to follow the load quasi-statically, so it just deflects by p0/kp_0/k. At high β\beta (fast forcing) Rd→0R_d \to 0: the mass cannot keep up and barely moves, no matter how hard you push. In between, near β=1\beta = 1, the two effects cancel in the denominator of (6) and the amplitude peaks sharply for light damping. That peak is resonance, and the markers sitting exactly on the curves confirm that the engine and the formula are the same physics.

The companion curve is the phase angle ϕ\phi, the lag of the response behind the force.

<Figure size 962x442 with 1 Axes>
<Figure size 962x442 with 1 Axes>

Figure 4:Phase lag ϕ\phi of the steady-state response behind the force, versus frequency ratio, for four damping ratios.

The phase tells you who is in charge. Below resonance the spring dominates and the structure tracks the force (ϕ≈0\phi \approx 0). Above resonance the mass dominates and the structure fights the force (ϕ≈180∘\phi \approx 180^\circ). The hand-off is at β=1\beta = 1, where ϕ=90∘\phi = 90^\circ regardless of damping: the response there is governed entirely by the dashpot, which is the whole story of the next section.

3Resonance: damping is all that is left

With β=1\beta = 1 exactly, the first term of the denominator in (6) vanishes, leaving

Rd(β=1)=12ζ,u0=p0k 12ζ.R_d(\beta{=}1) = \frac{1}{2\zeta}, \qquad u_0 = \frac{p_0}{k}\,\frac{1}{2\zeta}.

The static deflection is multiplied by 1/2ζ1/2\zeta, a factor of 10 at our 5 % damping. But that final amplitude is not reached instantly; it has to build up, as the next run from rest shows.

<Figure size 988x416 with 1 Axes>
<Figure size 988x416 with 1 Axes>

Figure 5:Driving at resonance (β=1\beta=1) from rest: the response (solid) climbing toward the steady-state envelope ±(p0/k)/2ζ\pm(p_0/k)/2\zeta (dashed).

The envelope of the build-up follows (1−e−ζωnt)\big(1 - e^{-\zeta\omega_n t}\big), and the reason is the same superposition we used for the steady state. At t=0t=0 the system is at rest, so the transient must start out exactly canceling the steady-state sinusoid (the two add to zero). The transient is a free vibration and therefore decays as e−ζωnte^{-\zeta\omega_n t} (Chapter 2); as it dies, the cancellation it was providing fades, and the response climbs from zero toward the full steady amplitude like (1−e−ζωnt)\big(1 - e^{-\zeta\omega_n t}\big). Lighter damping means a slower decay and a higher ceiling reached over more cycles. A short transient blast at resonance may be survivable simply because it ends before the amplitude has grown, which is exactly the question Chapter 5 takes up for pulses and shocks. Example 2 puts a number on the build-up time.

The next cell reads the peak of each cycle off the build-up run and finds the first one above 90 % of the steady amplitude.

cycle  1: peak  27.0 mm   theory  27.0 mm
cycle  2: peak  46.7 mm   theory  46.7 mm
cycle  4: peak  71.6 mm   theory  71.5 mm
cycle  7: peak  88.9 mm   theory  88.9 mm
cycle  8: peak  91.9 mm   theory  91.9 mm
cycle 12: peak  97.7 mm   theory  97.7 mm
first cycle above 90 %: 8    (ln 10 / (2 pi zeta) = 7.3 cycles, 4.6 s)

4The frequency-response function H(ω)H(\omega)

Everything above is encoded in one complex-valued function, and complex numbers make the algebra trivial. Feed the oscillator a unit complex harmonic p(t)=eiωtp(t)=e^{i\omega t} and look for a steady response of the same form, u(t)=H(ω) eiωtu(t)=H(\omega)\,e^{i\omega t}, with HH a complex amplitude to be found. Because each time derivative of eiωte^{i\omega t} just multiplies by iωi\omega, the equation of motion mu¨+cu˙+ku=eiωtm\ddot u + c\dot u + ku = e^{i\omega t} becomes purely algebraic: (−mω2+icω+k)H eiωt=eiωt\big(-m\omega^2 + i c\omega + k\big)H\,e^{i\omega t} = e^{i\omega t}. Cancel the common eiωte^{i\omega t} and solve for HH:

H(ω)=1k−mω2+i c ω=1k 1(1−β2)+i 2ζβ,H(\omega) = \frac{1}{k - m\omega^2 + i\,c\,\omega} = \frac{1}{k}\,\frac{1}{(1-\beta^2) + i\,2\zeta\beta},

where the second form divides through by kk exactly as in the RdR_d derivation. This frequency-response function (FRF) is the transfer function of the structure. It is not new physics but the steady-state result repackaged: its magnitude is the amplitude gain per unit force, ∣H∣=Rd/k|H| = R_d/k, and its phase is the lag, ∠H=−ϕ\angle H = -\phi (the minus sign because u0sin⁡(ωt−ϕ)u_0\sin(\omega t-\phi) lags the drive). Plotting both against frequency is a Bode plot, the everyday tool of vibration testing. The magnitude below is in amplitude decibels, 20log⁡10∣H∣20\log_{10}|H|, normalized to its peak, so a level of -3 dB means an amplitude of 1/21/\sqrt2 of the peak and a power of one half.

<Figure size 962x650 with 2 Axes>
<Figure size 962x650 with 2 Axes>

Figure 6:The frequency-response function H(ω)H(\omega) as a Bode plot: magnitude in decibels (top) and phase (bottom) versus frequency ratio, with the -3 dB half-power level marked on the magnitude.

4.1Half-power bandwidth: reading ζ\zeta off the peak

The Bode plot holds a payoff for an experimenter. The peak of ∣H∣|H| sits at Rd=1/2ζR_d=1/2\zeta (for light damping), so ∣H∣2|H|^2 peaks at 1/(2ζk)21/(2\zeta k)^2. The half-power points are the two frequencies where ∣H∣2|H|^2 has fallen to half that peak (hence “half power”; in amplitude they are ∣H∣max⁡/2|H|_{\max}/\sqrt2, which is 3 dB down). Setting ∣H∣2=12∣H∣max⁡2|H|^2 = \tfrac12|H|^2_{\max} in (10) and canceling means the denominator (1−β2)2+(2ζβ)2(1-\beta^2)^2+(2\zeta\beta)^2 must equal twice its value at the peak, which (for light damping, where the peak is essentially at β=1\beta=1) reduces to (1−β2)2=(2ζβ)2(1-\beta^2)^2 = (2\zeta\beta)^2, i.e. 1−β2=±2ζβ≈±2ζ1-\beta^2 = \pm 2\zeta\beta \approx \pm2\zeta. So β2≈1∓2ζ\beta^2\approx 1\mp 2\zeta and, taking the square root for small ζ\zeta, the two roots straddle the peak symmetrically:

β1,2≈1∓ζ⇒ζ≈β2−β12=Δf2fn.\beta_{1,2} \approx 1 \mp \zeta \quad\Rightarrow\quad \zeta \approx \frac{\beta_2 - \beta_1}{2} = \frac{\Delta f}{2 f_n}.

So you do not need to know the force, the mass, or the stiffness: just sweep the frequency, find the peak, and measure how wide it is at the -3 dB level. Let us recover the damping of our frame from its own FRF, pretending we only have the measured curve.

half-power band:  beta1 = 0.9462   beta2 = 1.0464
estimated  zeta = (beta2 - beta1)/2 = 0.0501
true       zeta = 0.0500

The estimate lands within a fraction of a percent of the true value. This half-power (3 dB) bandwidth method is one of the most common ways damping is measured on real structures: from a single forced-vibration test you read the period off the peak location and the damping off the peak width.

5Beating: two frequencies, almost equal

Drive a lightly damped structure at a frequency close to, but not equal to, its natural frequency, and the transient does not simply die. For a while it is nearly as large as the steady state, and the two sinusoids, at ω\omega and ωn\omega_n, drift slowly in and out of phase. The result is beating: a fast oscillation inside a slowly pulsing envelope.

<Figure size 1014x416 with 1 Axes>
quiet points at t = [ 6.15 12.42 18.7  24.98] s, spacing 6.28 s   (2 pi / |omega - omega_n| = 6.28 s)
<Figure size 1014x416 with 1 Axes>
quiet points at t = [ 6.15 12.42 18.7  24.98] s, spacing 6.28 s   (2 pi / |omega - omega_n| = 6.28 s)

Figure 7:Beating in a lightly damped frame (ζ=0.01\zeta=0.01) driven just off resonance (β=1.1\beta=1.1), with the slowly pulsing envelope dashed.

The carrier wave runs at the average frequency (ω+ωn)/2(\omega+\omega_n)/2, while the envelope swells and fades once every beat period Tb=2π/∣ω−ωn∣T_b = 2\pi/|\omega-\omega_n|, so the closer the drive is to resonance, the slower and longer the beats. Here ω=11\omega = 11 rad/s and ωn=10\omega_n = 10 rad/s, so Tb=2πT_b = 2\pi s, and the quiet points of Figure 7 indeed fall about 6.3 s apart. With finite damping the natural-frequency tone fades, the beats with it, and the motion relaxes to the steady state of Figure 2. Beating is therefore a transient signature of a structure forced near resonance: hear it as the throb of an engine running just off a structure’s tune.

6Base excitation and transmissibility

So far the force pushed the mass; now let the base move instead, as when a machine vibrates the floor it sits on or traffic shakes a building. From Chapter 1, a harmonic base acceleration u¨g=agsin⁡(ωt)\ddot u_g = a_g\sin(\omega t) enters the equation of motion as the effective force peff=−m u¨gp_\text{eff} = -m\,\ddot u_g. The engineering question flips: how much of the base motion is transmitted to the mass? The answer is the transmissibility TR, the ratio of the transmitted (absolute mass) acceleration amplitude to the input base-acceleration amplitude:

TR(β,ζ)=1+(2ζβ)2(1−β2)2+(2ζβ)2.\mathrm{TR}(\beta,\zeta) = \sqrt{\frac{1 + (2\zeta\beta)^2}{(1-\beta^2)^2 + (2\zeta\beta)^2}}.

The denominator is just the RdR_d resonance shape we already derived, because the base drives the same oscillator through the same (1−β2)+i2ζβ(1-\beta^2)+i2\zeta\beta. The extra 1+(2ζβ)21+(2\zeta\beta)^2 in the numerator is the new part. The mass feels the base not directly but through the spring and the dashpot in parallel, so the force reaching it combines a spring part, proportional to the relative motion, with a dashpot part, proportional to 2ζβ2\zeta\beta times it. The two parts are 90∘90^\circ out of phase and add in quadrature, which is exactly the 1+(2ζβ)21+(2\zeta\beta)^2 factor. (The same ratio governs the force transmitted through a mount.) Rather than carry that algebra further, we read TR straight from the engine: drive with a known base acceleration, recover the total acceleration of the mass (u¨+u¨g\ddot u + \ddot u_g), and take the amplitude ratio.

TR engine vs formula at beta=1.5, zeta=0.10: 0.8121 0.8122
<Figure size 962x520 with 1 Axes>
<Figure size 962x520 with 1 Axes>

Figure 8:Transmissibility TR\mathrm{TR} versus frequency ratio for several damping ratios (markers = engine; lines = closed form), with the β=2\beta=\sqrt2 crossover marked.

The crossover at β=2\beta=\sqrt2, where every curve passes through TR=1\mathrm{TR}=1 regardless of damping, is the central fact of vibration isolation. Below it, the mount makes things worse (TR > 1); only by tuning the system soft, pushing β\beta above 2\sqrt2, does the mass feel less than the floor. And the counter-intuitive twist: in the isolation region, adding damping raises TR. Damping tames the resonance peak but spoils the high-frequency roll-off: the classic isolation trade-off.

7Periodic but not harmonic: the Fourier route

Most repeating loads are not pure sinusoids: a reciprocating engine delivers a periodic train of pulses, and a footfall pattern repeats a sharp double hump. The key idea, and the reason this chapter generalizes so cleanly, is superposition in frequency. Any periodic force of period T0T_0 is a sum of harmonics at ω0=2π/T0\omega_0 = 2\pi/T_0 and its multiples (a Fourier series):

p(t)=∑nPn einω0t.p(t) = \sum_{n} P_n\, e^{i n \omega_0 t}.

Because the structure is linear, superposition applies: the response to the sum is the sum of the responses. Each harmonic Pneinω0tP_n e^{in\omega_0 t} is exactly the complex harmonic drive of the FRF section, so it produces H(nω0) Pneinω0tH(n\omega_0)\,P_n e^{in\omega_0 t}, scaled and phase-shifted by the frequency-response function (10) at that harmonic’s frequency. Adding them back:

u(t)=∑nH(nω0) Pn einω0t.u(t) = \sum_n H(n\omega_0)\,P_n\, e^{i n \omega_0 t}.

So we never need a new solver: take the FFT of one period to get the PnP_n, multiply each by H(nω0)H(n\omega_0), and add the responses back up. A real force has conjugate-symmetric coefficients (P−n=Pn‾P_{-n}=\overline{P_n}), so the +n+n and −n-n terms combine into a single real cosine. That is the origin of the factor of 2 and the Re⁡(⋅)\operatorname{Re}(\cdot) that appear in the code below, which keeps only the non-negative harmonics from NumPy’s real FFT. Let us do exactly that for a periodic triangle-wave force and check it against a direct time-history run of the engine.

<Figure size 1092x390 with 2 Axes>
<Figure size 1092x390 with 2 Axes>

Figure 9:A periodic triangle-wave force (left) and its harmonic content from the FFT of one period (right).

The triangle wave carries only odd harmonics, their amplitudes falling off as 1/n21/n^2 (Figure 9). Now build the response harmonic by harmonic with HH, and overlay the direct engine run.

<Figure size 1014x403 with 1 Axes>
max relative difference over the steady state: 0.87 %
harmonic 1: force 1.621 kN  x  R_d =  1.12  ->  response 9.11 mm
harmonic 3: force 0.180 kN  x  R_d = 10.00  ->  response 9.01 mm
harmonic 5: force 0.065 kN  x  R_d =  0.56  ->  response 0.18 mm
<Figure size 1014x403 with 1 Axes>
max relative difference over the steady state: 0.87 %
harmonic 1: force 1.621 kN  x  R_d =  1.12  ->  response 9.11 mm
harmonic 3: force 0.180 kN  x  R_d = 10.00  ->  response 9.01 mm
harmonic 5: force 0.065 kN  x  R_d =  0.56  ->  response 0.18 mm

Figure 10:Steady-state response to the triangle-wave force: the dashed curve sums the individual harmonic responses (H(nω0)PnH(n\omega_0)P_n) from the FFT, and the solid curve is a single direct run of the engine on the full load.

The two routes agree to within 1 %, and the Fourier picture is more than a computational trick, because it explains the response. Any harmonic of the load that lands near ωn\omega_n is amplified by Rd≈1/2ζR_d \approx 1/2\zeta. Here T0=3TnT_0 = 3T_n, so the third harmonic falls exactly on resonance: its force is only one ninth of the fundamental’s (0.180 against 1.621 kN), but Rd=10R_d = 10 lifts its response to 9.01 mm, as large as the 9.11 mm of the fundamental. That is why the response above mixes two frequencies of equal strength, a slow swing at the load period with a fast ripple at the natural period, and why a slow periodic load can shake a structure hard. This is the bridge to the frequency-domain view used throughout signal-based structural health monitoring, and the complementary, time-domain superposition (Duhamel’s integral, for loads that do not repeat) is the subject of Chapter 5.

8Summary

Every load in this chapter repeated forever, and Chapter 5 turns to loads that do not: a single impulse, a step, a short pulse, or a measured force history with no pattern at all. The same engine handles them unchanged, and the impulse response it produces there is the time-domain twin of the frequency-response function H(ω)H(\omega) met here. Where this chapter added harmonics, the next one adds impulses, and the two views describe the same linear oscillator.