Chapter 8 took a building apart into modes and showed that each one is just an SDOF oscillator. That fact underlies the way codes design buildings for earthquakes, and this chapter puts it to work. We ask the two questions a structural engineer must answer for every building:

  1. What is the peak demand? A full response history answers it for one record but needs a complete integration. Because each mode is an SDOF, we can instead read its peak straight off a response spectrum and combine the modes, with no response history at all: this is modal response-spectrum analysis (RSA).

  2. What forces does the code require us to design for? Building codes wrap the response spectrum, the modal idea, and the ductility of Chapter 7 into two procedures, the equivalent lateral force method and modal RSA, reduced by a response modification factor RR. We build the ASCE 7 version from scratch.

Everything here stands on chapters you already know: the response spectrum of Chapter 6, the modes and participation factors of Chapter 8, and the strength-for-ductility trade of Chapter 7. We are not learning new physics: we are assembling the old physics into the workflow of a design office. The chapter’s five-story building carries that whole workflow, from its modes to the forces on its floors.

1A five-story building and its modes

We need a slightly bigger building than Chapter 8’s three stories, so the modal and code effects have room to show. We take a five-story shear building, the same idealization as before (lumped floor masses, story springs), with stiffer lower stories and a lighter roof, as is common in real buildings, and the assembly is exactly the Chapter-8 code.

mode 1:  Tn = 0.598 s   Gamma =  +1.31   effective mass = 84.5 %
mode 2:  Tn = 0.221 s   Gamma =  -0.45   effective mass = 10.4 %
mode 3:  Tn = 0.143 s   Gamma =  +0.21   effective mass =  3.1 %
mode 4:  Tn = 0.113 s   Gamma =  -0.07   effective mass =  1.3 %
mode 5:  Tn = 0.095 s   Gamma =  +0.01   effective mass =  0.8 %

The fundamental period is T1≈0.60T_1 \approx 0.60 s and the first mode carries about 85 % of the building’s mass; the first two together reach about 95 % (and the first three reach 98 %). As in Chapter 8, a handful of modes will be plenty. We plot the mode shapes and tag each with its effective mass, the number that says how much each mode matters for an earthquake.

<Figure size 1248x468 with 5 Axes>
<Figure size 1248x468 with 5 Axes>

Figure 1:The five mode shapes of the building against floor height, each scaled to unit roof displacement on its own horizontal scale and labeled with its period and its effective modal mass as a share of the total mass.

2Peak demand without a time history: response-spectrum analysis

Here is the payoff of “every mode is an SDOF,” previewed in Figure 2 for the first two modes of the building. Each mode has its own period, and the response spectrum of the record gives the peak pseudo-acceleration at that period. Applied to the floor masses in the shape of the mode, that acceleration gives a set of modal floor forces, whose sum is the modal base shear. The forces of mode 2 point against its drawn shape because its participation factor is negative, and they partly cancel, so its base shear of 171 kN is far smaller than the 1079 kN of mode 1.

Response-spectrum analysis of the first two modes: each mode’s period (left) locates a pseudo-acceleration on the record’s spectrum (middle), which drives floor forces in the shape of the mode (right) whose sum is the modal base shear.

Figure 2:Response-spectrum analysis of the first two modes: each mode’s period (left) locates a pseudo-acceleration on the record’s spectrum (middle), which drives floor forces in the shape of the mode (right) whose sum is the modal base shear.

Formally, the modal equation from Chapter 8,

q¨r+2ζrωr q˙r+ωr2 qr=− Γr u¨g(t),\ddot q_r + 2\zeta_r\omega_r\,\dot q_r + \omega_r^2\,q_r = -\,\Gamma_r\,\ddot u_g(t),

is a unit-mass oscillator of period TrT_r and damping ζr\zeta_r, driven by the ground motion scaled by Γr\Gamma_r. We already have a tool that reports the peak of such an oscillator over an entire record without integrating it for our particular building: the response spectrum of Chapter 6. Reading the deformation spectrum at the modal period gives the peak modal coordinate directly:

∣qr∣max⁡=∣Γr∣ Sd(Tr,ζr),|q_r|_{\max} = |\Gamma_r|\,S_d(T_r,\zeta_r),

because Sd≥0S_d\ge 0 is by definition the peak displacement of a unit oscillator under this record. The peak contribution of mode rr to the floor displacements is then that modal coordinate spread over the mode shape, ur=ϕr ΓrSd(Tr)\mathbf{u}_r = \boldsymbol{\phi}_r\,\Gamma_r S_d(T_r). The sign of Γr\Gamma_r is kept here, since it is carried into the signed contribution before the modes are combined. The peak base shear carried by mode rr follows from the equivalent static modal force fr=ΓrSa(Tr) Mϕr\mathbf{f}_r = \Gamma_r S_a(T_r)\,\mathbf{M}\boldsymbol{\phi}_r as

Vr=1Tfr=Γr Lr Sa(Tr)=Mr⋆ Sa(Tr),Lr=ϕrTM1,  Mr⋆=Γr2Mr,V_r = \boldsymbol{1}^\mathsf{T}\mathbf{f}_r = \Gamma_r\,L_r\,S_a(T_r) = M_r^\star\,S_a(T_r), \qquad L_r=\boldsymbol{\phi}_r^\mathsf{T}\mathbf{M}\boldsymbol{1},\ \ M_r^\star=\Gamma_r^2 M_r,

the effective modal mass times the spectral acceleration, a remarkably clean result. Each mode’s peak demand is one lookup on the spectrum. We compute them for our building under the Chapter-6 synthetic record, scaled to a peak ground acceleration of 0.4 g.

mode 1:  Sa = 0.449 g   peak roof contribution =  52.1 mm   modal base shear =   1079 kN
mode 2:  Sa = 0.579 g   peak roof contribution =   3.2 mm   modal base shear =    171 kN
mode 3:  Sa = 0.594 g   peak roof contribution =   0.6 mm   modal base shear =     52 kN
mode 4:  Sa = 0.565 g   peak roof contribution =   0.1 mm   modal base shear =     20 kN
mode 5:  Sa = 0.420 g   peak roof contribution =   0.0 mm   modal base shear =      9 kN

2.1Combining the modes: SRSS and CQC

There is one subtlety, and it is the whole art of RSA. The spectrum gives each mode’s peak, but the modes do not peak at the same instant, as Figure 3 shows for this building and record. The base shear of mode 1 peaks at 6.04 s, that of mode 2 at 5.10 s, and the building’s total at 5.42 s, at 1136 kN. Adding the peaks of all five modes gives 1332 kN, an upper bound that overestimates the response-history peak by 17 %, so the modes are instead combined statistically.

Base shear of the building under the record from mode 1, from mode 2 and from all five modes together, each reaching its peak at a different instant.

Figure 3:Base shear of the building under the record from mode 1, from mode 2 and from all five modes together, each reaching its peak at a different instant.

The workhorse rule is SRSS, the square root of the sum of squares (Rosenblueth, 1951), which treats the modal peaks as independent:

rmax⁡≈∑rrr2.r_{\max} \approx \sqrt{\textstyle\sum_r r_r^2}.

SRSS is excellent when the natural periods are well separated. When two periods are close (common in three-dimensional buildings with nearly equal lateral and torsional periods), their responses are correlated and SRSS can err. Correlation-based rules go back to Rosenblueth and Elorduy (1969); the one in wide use today is the complete quadratic combination (CQC) (Wilson, Der Kiureghian, and Bayo, 1981), which fixes this with cross-terms weighted by a correlation coefficient ρrs\rho_{rs} (Der Kiureghian, 1981):

rmax⁡≈∑r∑sρrs rr rs,ρrs=8ζ2(1+β) β3/2(1−β2)2+4ζ2β(1+β)2,β=ωsωr,r_{\max} \approx \sqrt{\textstyle\sum_r\sum_s \rho_{rs}\,r_r\,r_s}, \qquad \rho_{rs} = \frac{8\zeta^2(1+\beta)\,\beta^{3/2}} {(1-\beta^2)^2 + 4\zeta^2\beta(1+\beta)^2}, \quad \beta = \frac{\omega_s}{\omega_r},

which equals 1 on the diagonal (β=1\beta=1) and decays toward 0 as the periods separate, so CQC collapses to SRSS for well-spaced modes and only differs when modes are close. The next cell implements both rules and compares them for our building.

largest correlation between two different modes: rho = 0.245 (modes 4 and 5)
base shear:  SRSS = 1094 kN   CQC = 1096 kN

The largest correlation, 0.245, couples modes 4 and 5, whose periods are close, but those two modes carry only about 2 % of the mass. CQC and SRSS therefore give nearly the same base shear here, 1096 kN against 1094 kN.

2.2How good is it? RSA versus a full response history

RSA is an estimate of the peak, and with the record’s own spectrum the modal combination is its only approximation. To see how good it is, we compute the full response history (RHA) of all five modal SDOFs with the same exact solver that built the spectrum, recombine them as in Chapter 8, and compare peaks.

mode 1 base shear peaks at t = 6.04 s:  1079 kN
mode 2 base shear peaks at t = 5.10 s:  171 kN
total base shear peaks at t = 5.42 s:  1136 kN
sum of the five modal peaks = 1332 kN (+17.3%)
base shear:  RHA = 1136 kN   SRSS = 1094 kN (-3.7%)   CQC = 1096 kN (-3.5%)
floor displacement, SRSS against RHA:    [-3.7 -3.5 -1.9 -0.1  2.2] %
floor displacement, mode 1 against RHA:  [-5.  -4.1 -2.  -0.1  2. ] %
<Figure size 702x546 with 1 Axes>
<Figure size 702x546 with 1 Axes>

Figure 4:Peak floor displacements of the building from the response history (gray band), the SRSS and CQC response-spectrum estimates (markers), and the first mode alone (dotted).

Figure 4 is the justification for the entire method. The response-spectrum estimate stays within 4 % of the response history at every floor and in the base shear, and even the first mode alone stays within 5 %. With a record’s own spectrum, as here, RSA saves little work, because computing the spectrum takes one response history per period. Its value in design comes from the smooth code spectrum of the next section, which replaces the record altogether: one eigenvalue solve, one spectrum lookup per mode and a statistical combination then give the design demands.

3From response spectra to design spectra

The spectrum we just used was the jagged fingerprint of one record. As Chapter 6 warned, you cannot design to one earthquake’s accidents. Codes replace it with a smooth design spectrum anchored to the site hazard by two parameters: SDSS_{DS}, the design spectral acceleration in the short-period (acceleration-controlled) plateau, and SD1S_{D1}, the value at a period of one second (the velocity-controlled branch). The ASCE 7 shape, written here with the standard’s own symbols, turns the Newmark and Hall idea of Chapter 6 into a formula:

Sa(T)={SDS (0.4+0.6 T/T0),T<T0,SDS,T0≤T≤TS,SD1/T,TS<T≤TL,SD1 TL/T2,T>TL,T0=0.2 SD1SDS,TS=SD1SDS.S_a(T) = \begin{cases} S_{DS}\,(0.4 + 0.6\,T/T_0), & T < T_0,\\[3pt] S_{DS}, & T_0 \le T \le T_S,\\[3pt] S_{D1}/T, & T_S < T \le T_L,\\[3pt] S_{D1}\,T_L/T^2, & T > T_L, \end{cases} \qquad T_0 = 0.2\,\frac{S_{D1}}{S_{DS}},\quad T_S = \frac{S_{D1}}{S_{DS}}.

The flat plateau is the acceleration-controlled region; the 1/T1/T branch is velocity-controlled; the 1/T21/T^2 tail past the long-period corner TLT_L is displacement-controlled. These are exactly the three regions we read off a real spectrum in Chapter 6, and we code the shape once.

T0 = 0.12 s   TS = 0.60 s
design Sa at the modal periods (g): [1.    1.    1.    0.964 0.874]
<Figure size 962x468 with 1 Axes>
<Figure size 962x468 with 1 Axes>

Figure 5:The ASCE 7 design spectrum (orange) for SDS=1.0S_{DS}=1.0 g and SD1=0.6S_{D1}=0.6 g, with the corner periods T0T_0 and TST_S and the building’s five modal periods marked.

All five modal periods land on or near the peak of this spectrum. Mode 1, at 0.598 s, sits just inside the corner TS=0.60T_S = 0.60 s at the end of the plateau, and modes 2 and 3 fall on the plateau. The two stiffest modes, with periods below T0=0.12T_0 = 0.12 s, sit on the short-period rising branch at 0.96 g and 0.87 g. Every mode is therefore driven near the peak spectral acceleration.

4The equivalent lateral force method

The simplest code procedure does not even need the modes. The equivalent lateral force (ELF) method (American Society of Civil Engineers, 2022) approximates the whole earthquake demand as a single set of static floor forces, built on the first mode alone, in three steps. Each step replaces one piece of the modal analysis with a code formula: the eigenvalue solve, the spectrum lookup and the mode shape.

Step 1, the period: rather than an eigenvalue solve, codes allow an empirical approximate period Ta=CthnxT_a = C_t h_n^{x} from the building height hnh_n and a system-dependent pair (Ct,x)(C_t, x). ASCE 7 tabulates the pair for each structural system; for a concrete moment frame it is Ct=0.0466C_t = 0.0466 and x=0.9x = 0.9, with hnh_n in meters. (Our eigen solve gave T1=0.60T_1=0.60 s; the formula should land nearby.)

Step 2, the base shear: the total horizontal force is V=CsWV = C_s W, where WW is the seismic weight and the seismic response coefficient

Cs=SDSR/Ie,Cs≤SD1T (R/Ie)  (T≤TL),Cs≥max⁡(0.044 SDSIe, 0.01),C_s = \frac{S_{DS}}{R/I_e}, \qquad C_s \le \frac{S_{D1}}{T\,(R/I_e)}\ \ (T\le T_L),\qquad C_s \ge \max(0.044\,S_{DS}I_e,\ 0.01),

is the design spectral acceleration SaS_a divided by R/IeR/I_e, the design spectrum cut down by the response modification factor (next section) and scaled up by the importance factor IeI_e. The cap enforces the 1/T1/T branch for taller buildings; the floor guarantees a minimum strength.

Step 3, the vertical distribution: the base shear is spread up the height in proportion to floor weight times height (raised to a period-dependent power kk that tilts the profile from triangular toward parabolic for tall, long-period buildings):

Fx=Cvx V,Cvx=wxhx k∑iwihi k.F_x = C_{vx}\,V, \qquad C_{vx} = \frac{w_x h_x^{\,k}}{\sum_i w_i h_i^{\,k}}.

We carry all three steps out for our building, taking it as a special reinforced concrete moment frame (R=8R=8, Cd=5.5C_d=5.5, Ie=1I_e=1) in a high-seismic region, with 3.5 m stories. Example 1 works out the base shear of this building by hand.

The next cell repeats Example 1 and also gives the forces on every floor, the story shears and the amplified story drifts.

approximate period  Ta = 0.613 s   (eigen gave T1 = 0.598 s, +2.5%);  exponent k = 1.06
seismic weight       W = 2845 kN
response coefficient Cs = 0.1224   ->   base shear V = 348 kN
  level 1:  Fx =  23.0 kN = 0.066 V  (first mode: 0.074 V)   story shear = 348.3 kN   amplified drift = 0.61 %
  level 2:  Fx =  47.8 kN = 0.137 V  (first mode: 0.150 V)   story shear = 325.4 kN   amplified drift = 0.64 %
  level 3:  Fx =  73.3 kN = 0.211 V  (first mode: 0.224 V)   story shear = 277.6 kN   amplified drift = 0.62 %
  level 4:  Fx =  99.4 kN = 0.285 V  (first mode: 0.285 V)   story shear = 204.2 kN   amplified drift = 0.53 %
  level 5:  Fx = 104.8 kN = 0.301 V  (first mode: 0.267 V)   story shear = 104.8 kN   amplified drift = 0.33 %

The empirical period Ta=0.61T_a=0.61 s lands within 3 % of the eigenvalue answer, partly through the choice of story stiffnesses: the formula is a fit to periods measured in real buildings, and it deliberately errs on the short side, which raises the design force. The lateral forces grow with height, and the roof, though lightest, attracts the largest force, because the code weights each floor by its height raised to k=1.06k = 1.06. The first mode’s own inertia forces, mjϕj1m_j\phi_{j1}, peak one level lower, at level 4, because the roof’s smaller mass outweighs its larger displacement, so the code pattern is a simple, slightly top-heavy stand-in for the first mode. We draw the force pattern and the story drifts it implies.

<Figure size 1170x520 with 2 Axes>
<Figure size 1170x520 with 2 Axes>

Figure 6:The equivalent lateral forces FxF_x on the building, largest at the roof (left), and the story-drift ratios amplified by CdC_d against the 2 % limit (right).

The amplified story drifts range from 0.33 % in the top story to 0.64 % in the second, comfortably under the 2 % limit for a building of ordinary occupancy, so the building passes the drift check. The second story drifts most because its story shear is nearly as large as the first story’s while its stiffness is lower. The top story drifts least, because it carries only the roof force.

5The R factor: designing for less than the elastic force

We have quietly done something remarkable: divided the demand by R=8R=8. Where does that come from, and why is it allowed? The answers lead straight back to the strength-for-ductility trade of Chapter 7.

If the building had to remain elastic through the design earthquake, it would have to carry the full spectral force, with no division by RR. Let us compute that elastic demand with a modal RSA on the design spectrum, first by hand for three modes in Example 2, and compare it to what we actually designed for.

The next cell repeats Example 2 and prints every number quoted in it.

periods (s): [0.598 0.221 0.143]    Sa (g): [1. 1. 1.]
effective masses (t): [245.   30.1   9. ]    modal base shears (kN): [2403.   295.4   88.2]
SRSS = 2423 kN   absolute sum = 2787 kN (+15.0%)   SRSS / R = 303 kN

The next cell repeats the calculation with all five modes.

elastic base shear  (R = 1)        = 2423 kN   = 0.85 W
design base shear   V_elastic / R  = 303 kN
ELF design base shear  Cs * W      = 348 kN
design spectrum at T1: Sa = 1.000 g, divided by R: 0.125 g

The elastic demand is enormous, about 0.85 W0.85\,W (nearly the building’s whole weight pushed sideways), and designing for it would be wildly uneconomic. Instead we design for roughly one-eighth of it, and the building survives the rest by yielding, exactly the strength-for-ductility trade of Chapter 7, now at building scale. The response modification factor bundles two separate effects into one number:

The code folds the two into a single factor, their product RR. The design spectrum divided by RR is the force you proportion members to; the structure makes up the difference by yielding. And because it yields, its real displacements are larger than the reduced-force analysis predicts, which is why drifts were multiplied back up by the deflection amplification factor CdC_d in the drift check. Figure 7 shows the whole bargain on one plot: at the building’s fundamental period the elastic demand of 1.0 g is cut by the factor R=8R=8 to a design level of 0.125 g, and the gap between the two is covered by inelastic action.

<Figure size 962x494 with 1 Axes>
<Figure size 962x494 with 1 Axes>

Figure 7:The elastic design spectrum (gray) and the force the structure is actually proportioned to, Sa/RS_a/R (orange), against period, with the gap at the fundamental period (dashed) annotated as the portion covered by ductility and overstrength.

6Putting it together

Three procedures, one building, and answers that fit together. The response history is the most complete of the three but needs a ground motion and an integrator. Modal RSA estimates its peaks from a spectrum and a statistical combination, with no response history. The ELF method boils the whole thing down to a static first-mode force pattern. Their answers fit together because they rest on the same modal physics, seen at different resolutions.

method                             base shear (kN)
--------------------------------------------------
RHA, response history (record)                1136
RSA, SRSS (record)                            1094
elastic demand on design spectrum             2423
  ... reduced by R = 8                         303
ELF, code static (design)                      348

factor that scales the RSA design base shear up to the ELF value: 1.15

The record-based RHA and RSA agree to within 4 %, the error of the modal combination. The elastic demand on the design spectrum is about twice as large, because the code spectrum represents the site’s design hazard rather than one record. Once divided by RR it lands close to the ELF base shear, 303 kN against 348 kN. Where the modal base shear falls below the ELF value, ASCE 7 requires the modal forces to be scaled up to it, here by a factor of 1.15. The two design routes are consistent, and codes choose between them by the building’s height and regularity, which decide when the simpler ELF method is permitted.

7Summary

This is where the whole book arrives: we began with one mass on a spring and the single equation mu¨+cu˙+ku=p(t)m\ddot u + c\dot u + ku = p(t). We built one numerical engine to solve it for any load, watched it ring, resonate, and yield, distilled its peaks into a response spectrum, and discovered that a building of any size is just a stack of those same oscillators. In this chapter those oscillators became the lateral forces an engineer writes on a drawing. The single degree of freedom was never a simplification to apologize for: it was the whole subject, and now the whole practice, in its smallest honest form.